Search
Wish list
Region
Region (be)
Products
Company
Focus on
Contact
de  en  pl  fr  hr  nl  hu  it  sv  sl  cn  es
Pipe entries

Modular seal

Modular pipe seal

GKD

Add to wish listAdd to wish list
Modular seal - Modular pipe seal
USP
  • with integrated installation control - no torque control key required
  • no retightening required
  • nuts moulded into the pressure plate, therefore no loose parts
For sealing of newly to install pipes or already installed pipes inside core drilled holes or wall sleeves. The modular structure allowes installation on all kind of pipes and diameter combinations.
Modular seal - Modular pipe seal
Data is sent to YouTube when the videos are played. The data protection statements of YouTube and Hauff-Technik apply.

Facts

Advantages:

  • Optimized bolt geometry
  • Made in Germany
  • available from stock
  • Suitable for retrofit sealing

Scope of delivery:

  • 1 piece of lubricating stick

Application range:

  • Waterproof concrete stress class 1 and 2

Material:

  • Rubber: EDPM or NBR
  • Screws and nuts: rust-free stainless steel V4A (AISI 316L)
  • Press plates: glass fibre reinforced polyamide

Tightness:

  • gastight and watertight
  • radon tight
Downloads

Brochures

Installation instructions

Test reports

Data sheet & tender specification

For download of data sheet and tender specification please configurate the product in the section below and download via the symbol Download symbol

Variants

Min. annular space (mm) Max. annular space (mm) Carrier pipe OD (mm) Required wall thickness (mm) Article code
12.7 16 21,3 - 323,9 75 X * GKD200 EPDM 1)
16 20 25 - 323,9 75 X * GKD275 EPDM 1)
18.5 23 58 - 463 100 X * GKD300 EPDM
23.25 26 60,3 - 463 100 X * GKD315 EPDM
24 30 152,2 - 716 110 X * GKD325 EPDM
25.5 34 30 - 323,9 120 X * GKD340 EPDM
32 42 40 - 406,4 120 X * GKD360 EPDM
36.5 43 168,3 - 1230 150 X * GKD400 EPDM
37 48.5 60,3 - 323,9 140 X * GKD410 EPDM
Expand


1) Due to the small size of the pressure plates, nuts are not moulded and without installation control.
X = number of links, Article number on demand. The complete article number is derived from the number of links

Configurator

Ø-carrier pipe outside (mm)

material
pipe diameter
coating
individual diameter input

Ø-wall opening inside (mm)

version
inner diameter
individual diameter input
circular chamber installation